<command>pg_resetwal</command> is unable to determine appropriate values
by reading <filename>pg_control</filename>. Safe values can be determined as
described below. For values that take numeric arguments, hexadecimal
- values can be specified by using the prefix <literal>0x</literal>.
+ values can be specified by using the prefix <literal>0x</literal>. Note
+ that these instructions only apply with the standard block size of 8 kB.
</para>
<variablelist>
greatest file name in the same directory. The file names are in
hexadecimal.
</para>
+ <!-- XXX: Should there be a multiplier, similar to the other options? -->
</listitem>
</varlistentry>
names are in hexadecimal, so the easiest way to do this is to specify
the option value in hexadecimal and append four zeroes.
</para>
+ <!-- 65536 = SLRU_PAGES_PER_SEGMENT * BLCKSZ / sizeof(MultiXactOffset) -->
</listitem>
</varlistentry>
The file names are in hexadecimal. There is no simple recipe such as
the ones for other options of appending zeroes.
</para>
+ <!-- 52352 = SLRU_PAGES_PER_SEGMENT * floor(BLCKSZ/20) * 4; see multixact.c -->
</listitem>
</varlistentry>
in <filename>pg_xact</filename>, <literal>-u 0x700000</literal> will work (five
trailing zeroes provide the proper multiplier).
</para>
+ <!-- 1048576 = SLRU_PAGES_PER_SEGMENT * BLCKSZ * CLOG_XACTS_PER_BYTE -->
</listitem>
</varlistentry>
in <filename>pg_xact</filename>, <literal>-x 0x1200000</literal> will work (five
trailing zeroes provide the proper multiplier).
</para>
+ <!-- 1048576 = SLRU_PAGES_PER_SEGMENT * BLCKSZ * CLOG_XACTS_PER_BYTE -->
</listitem>
</varlistentry>
</variablelist>